IT Infrastructure Setup & AMC

Structured Network Cabling

From the rack to every desk and device.

We design and install structured copper cabling that connects every workstation, phone, camera and access point back to your network rack, neatly routed, labelled and tested to recognised standards.

Structured Network Cabling
Cat6 & Cat6AThe right cable for each point
Tested linksEvery point tested before handover
Fully labelledFind any port in seconds
Ready to growSpare points and capacity planned in

Service overview

What's included

A structured cabling system is planned as a whole, not added one cable at a time, so it stays organised, reliable and easy to change.

  • Data point layout and design
  • Cat6 / Cat6A cable installation
  • Patch panels and wall outlets
  • Trunking, trays and containment
  • Labelling to an agreed scheme
  • Testing and documentation

How structured cabling works

The anatomy of a cabling channel

Every connection follows the same path from your network rack to a device. Structured cabling follows international standards that limit how long each part can be.

Network switchIn the rack
Patch cord
Patch panelLabelled ports
Horizontal cable in containment
Wall outletFaceplate
Patch cord
DevicePC, phone, camera, AP
Permanent link: up to 90 m
Full channel: up to 100 m end to end

Choosing the right cable

Cat6, Cat6A or fiber?

We match each run to its job, so you don't overspend on desks or under-spec your access points.

Cat6 copperCat6A copperMultimode fiber (OM3/OM4)Single-mode fiber (OS2)
Typical speed1 Gbps to 100 m; 10 Gbps on short runs (up to ~55 m)10 Gbps to 100 m10–100 Gbps within a building10 Gbps+ over kilometres
Typical distanceUp to 100 m channelUp to 100 m channelUp to a few hundred metresLong distances between buildings and sites
Best forDesks, phones, printers, camerasWi-Fi 6/7 access points, future-ready offices, server roomsRisers and backbones inside a building, data centresLinks between buildings, campuses and long routes
Carries power (PoE)YesYesNoNo

Typical values; actual performance depends on installation quality, equipment and route.

Key features

Cabling done properly, from the first point to the last

Point layout planning

Data points placed for desks, meeting rooms, cameras, access points and printers, with room for change.

Copper cabling

Cat6 and Cat6A runs installed within recommended lengths and bend limits.

Patch panels & outlets

Organised patch panels and faceplates, matched port-for-port with clear labels.

Containment

Trunking, cable trays and ceiling routes that protect cables and keep spaces tidy.

Testing

Each link tested for continuity and performance, with results recorded.

Documentation

Port maps, floor plans and test results handed over in one pack.

How we deliver

From floor plan to tested, labelled cabling

Every step ends with something you can check, so you always know where the project stands.

  1. STEP 01

    Site survey

    We review your floor plan, ceilings, routes and device locations.

    Survey notes
  2. STEP 02

    Point layout & design

    Every data point and cable route planned and agreed.

    Marked-up layout
  3. STEP 03

    Containment

    Trays, trunking and routes installed first.

    Routes in place
  4. STEP 04

    Pull & terminate

    Cables pulled, terminated at panels and outlets.

    Terminated points
  5. STEP 05

    Test & label

    Every link tested and labelled to the agreed scheme.

    Test results
  6. STEP 06

    Handover

    Port maps, plans and results delivered.

    Documentation pack

FAQs

Questions we hear most

About data points, cable types and installation.

Ask on WhatsApp
How many data points do we need per desk?

Most offices plan at least one or two points per desk, plus points for printers, meeting rooms, access points and cameras. We recommend a layout based on how you work and how you expect to grow.

Should we choose Cat6 or Cat6A?

Cat6 suits most desks and devices. Cat6A is recommended for Wi-Fi access points, server rooms and anywhere you want to be ready for faster speeds.

Can you add points to our existing cabling?

Yes. We extend existing systems, match your labelling scheme and test new and existing links.

Will the cabling work with our CCTV and phones?

Yes. Structured cabling carries data and Power over Ethernet for IP cameras, phones and access points.

Let's build a smarter, safer workplace.

Share your requirements and our technical team will get in touch to plan the right solution for your site.